Intelli-Tank Manual (106759) 12-15-03 – 3 – Class 1
When the unit is first powered up the lights will cycle on individually starting with
the EMPTY (output 1) light and then the lights will show the current status.
A Module connected to a Master unit (through the 1-wire data line) will mimic
the Master unit’s LED condition and flash rate.
A Module not connected to a Master unit will alternately flash the upper two
lights and the lower two lights. This indicates a “no data” condition.
Level indications:
LEVEL output 4 output 3 output 2 output 1
7/8 < LVL <= F ON ON ON ON
3/4 < LVL <= 7/8 FLASH .8Hz ON ON ON
5/8 < LVL <= 3/4 ON ON ON
1/2 < LVL <= 5/8 FLASH .8Hz ON ON
3/8 < LVL <= 1/2 ON ON
1/4 < LVL <= 3/8 FLASH .8Hz ON
1/8 < LVL <= 1/4 ON
1/16 < LVL <= 1/8 FLASH .8Hz
E <= LVL <= 1/16 FLASH 1.6Hz FLASH 1.6Hz FLASH 1.6Hz FLASH 1.6Hz
Auto-Fill Function
Auto-fill mode is active when the auto-fill select input (pin 8) is grounded. The
auto-fill status light output (pin 2) indicates the current status of this mode and is
capable of driving positive voltage to 250mA.
Status Light Condition
On
Auto-fill mode selected and is in standby
Flashing
Auto-fill mode selected and is currently filling
(refill output is active).
Off
Auto-fill mode de-selected or error condition is
present.